Research Article
A Multiport Electric Energy Routing Scheme Applied to Battery Energy Storage System
Table 3
Simulation model and experimental platform parameters.
| Parameters | Value |
| CF-IBDC module | Number of cascades j | M = 2 | Repurposed battery capacity C | 400 Ah | Repurposed battery SOC range | 20%∼80% | Rated input voltage VL | 48 V | Low-voltage bus voltage Vb | 100 V | High-voltage bus voltage VH | 100 V | Input filter capacitance CL | 470 μF | Transformer ratio n | 1 : 1 : 1 | Switching frequency fdc | 100 kHz | Rated power P | 250 W |
| Cascade H-bridge module | AC side level number 2i + 1 | 5 | Number of H-bridges cascades i | N = 2 | DC bus voltage Vdc | 200 V | Switching frequency fac | 5 kHz | Filter inductor Lf | 2.8 mH |
|
|