Research Article

Designing and Sensitivity Analysis of an Off-Grid Hybrid Wind-Solar Power Plant with Diesel Generator and Battery Backup for the Rural Area in Iran

Table 1

The effect of changing the intensity of sunlight and wind on the optimal values of the designed system.

Sunlight Wind speed (m/s)Reflects light from the environment (٪)Solar panel (kW)Wind turbine (kW)Diesel generator (kW)Battery 200ConverterNet present cost (NPC)Cost of generating energy ($/kWh)
(Ah)(kW)

4.0323.1520130217327020371
4.0323.1530130217327013371
4.0322.520130217327020371
4.0322.530130217327013371
4.0324208122232342362
4.0324308122232338361
415.320140217327597379
415.330140217327588379
45.220140217327597379
45.230140217327588379
44209122232893369
443091222326881369
515.320110217325877355
515.33090222325718353
55.220110217325877355
55.23090222325718353
542081217325383348
543081217325373348