Research Article

Application of Hybrid MOPSO Algorithm to Optimal Reactive Power Dispatch Problem Considering Voltage Stability

Table 8

Statistical results of performance metric for IEEE 30-bus and IEEE 118-bus systems.

Performance measuresIEEE 30-bus systemIEEE 118-bus system
NSGA-IIMOAE/DMOPSOHMOPSONSGA-IIMOAE/DMOPSOHMOPSO

GD
 Mean0.1136270.0153780.0158620.0127350.3305740.0229160.0248110.018853
 Std. dev.0.0371410.004140.0031350.0022830.0645780.0038670.0050950.003456
MSP
 Mean0.2635460.327520.2896320.1867520.2876580.415430.3256240.253628
 Std. dev.0.0402340.015640.024660.0113380.0584620.0031330.0382360.031247
HV
 Mean0.1857460.226760.2116510.248360.1323850.1536520.1657270.201435
 Std. dev.0.0355410.0315720.0417010.0258130.0423560.0558140.0632170.040472