Research Article
Induction Motor Stator Interturn Short Circuit Fault Detection in Accordance with Line Current Sequence Components Using Artificial Neural Network
Table 2
Comparison of phase current values of 5 hp motor obtained from simulation and experiment.
| S. no | Fault % in phase-A winding | Phase current values (A) obtained from | Error percentage | Experiment | Simulation |
| 1 | 0 | 10.2 | 10.1651 | 0.0034216 | 2 | 0.7 | 10.4 | 10.4259 | −0.0024904 | 3 | 1.4 | 10.7 | 10.6867 | 0.00124299 | 4 | 2.1 | 10.9 | 10.9476 | −0.00436697 | 5 | 3.5 | 11.2 | 11.1932 | 0.000607142 | 6 | 7 | 11.7 | 11.6899 | 0.000901785 | 7 | 10.5 | 12.2 | 12.2366 | −0.00300 | 8 | 15 | 12.6 | 12.6254 | −0.00201587 |
|
|