Research Article

Induction Motor Stator Interturn Short Circuit Fault Detection in Accordance with Line Current Sequence Components Using Artificial Neural Network

Table 2

Comparison of phase current values of 5 hp motor obtained from simulation and experiment.

S. noFault % in phase-A windingPhase current values (A) obtained fromError percentage
ExperimentSimulation

1010.210.16510.0034216
20.710.410.4259−0.0024904
31.410.710.68670.00124299
42.110.910.9476−0.00436697
53.511.211.19320.000607142
6711.711.68990.000901785
710.512.212.2366−0.00300
81512.612.6254−0.00201587