Research Article

Induction Motor Stator Interturn Short Circuit Fault Detection in Accordance with Line Current Sequence Components Using Artificial Neural Network

Table 3

Comparison of phase current values of 5 hp motor obtained from experiment and mathematical model.

S. noβ (fraction of shorted turns)Phase current values (A)Error percentage
Mathematical modelSimulation

10.00710.38610.4259−0.00384171
20.01410.69510.68670.007760636
30.02110.92110.9476−0.002435674
40.03511.19311.1932−0.001786831
50.0711.68411.6899−0.00504964
60.10512.24312.23660.0005227477
70.1512.63012.62540.0036421219
80.1812.82812.832−0.00311817