Research Article
Induction Motor Stator Interturn Short Circuit Fault Detection in Accordance with Line Current Sequence Components Using Artificial Neural Network
Table 4
Calculated parameter values.
| S. no | Percentage shorting in phase-winding | δ = [Ipositive − Inegative]/Ipositive |
| 1 | 0 | 1 | 2 | 0.233 | 0.99958121 | 3 | 0.467 | 0.999152787 | 4 | 0.7 | 0.998734682 | 5 | 0.933 | 0.998316917 | 6 | 1.167 | 0.997889539 | 7 | 1.4 | 0.997472461 | 8 | 1.633 | 0.997055722 | 9 | 1.867 | 0.99663929 | 10 | 2.1 | 0.996213288 | 11 | 2.333 | 0.995797568 | 12 | 3.5 | 0.991471595 | 13 | 4.667 | 0.987103194 | 14 | 5.833 | 0.982501398 | 15 | 7 | 0.977979806 | 16 | 8.167 | 0.973390758 | 17 | 9.333 | 0.968665628 | 18 | 10.5 | 0.963833373 |
|
|