Calculated parameter values.

S. noPercentage shorting in phase-windingδ = [Ipositive − Inegative]/Ipositive

101
20.2330.99958121
30.4670.999152787
40.70.998734682
50.9330.998316917
61.1670.997889539
71.40.997472461
81.6330.997055722
91.8670.99663929
102.10.996213288
112.3330.995797568
123.50.991471595
134.6670.987103194
145.8330.982501398
1570.977979806
168.1670.973390758
179.3330.968665628
1810.50.963833373