Research Article
Optimal Hybrid Renewable Energy System: A Comparative Study of Wind/Hydrogen/Fuel-Cell and Wind/Battery Storage
Table 5
Technical comparison of HRES scenarios.
|  Parameters | HRES 1 | HRES 2 |
| Total power generated (kWh/yr) | 39,805 | 14,739 | AC primary load served (kWh/yr) | 5,246 | 5,430 | DC load served (kWh/yr) | 501 | 517 | Excess electricity (kWh/yr) | 4,932 | 8,355 | Unmet electric load (kWh/yr) | 334 | 134 | Fuel-cell electric production (kWh/yr) | 14,611 | N/A | Hydrogen energy storage capacity (kWh) | 3,333 | N/A | Tank autonomy (hrs.) | 4,802 | N/A | Fuel-cell operation hours (hrs/yr) | 5,843 | N/A | Battery autonomy (hrs.) | N/A | 81 | Battery energy storage (kWh/yr) | N/A | 2.444 |
|
|