Research Article

Bus Voltage Stabilization Control of Photovoltaic DC Microgrid Based on Fuzzy-PI Dual-Mode Controller

Table 3

Comparison of performance indexes under different controlling strategies.

PI controllerFuzzy controllerFuzzy-PI controller

Initial power-upAdjustment time (s)0.40.20.2
Voltage overshoot (V)2.500
Steady-state error (V)00.80

Load’s surgeAdjustment time (s)0.80.20.2
Voltage variation (V)7.54.53.5
Steady-state error (V)01.20

Load’s sharp reductionAdjustment time (s)0.80.20.2
Voltage variation (V)10.50.3
Steady-state error (V)00.80