Research Article
Research on Improved Deadbeat Control Strategy Based on Interpolation Prediction and Online Inductance Identification
Table 2
Electrical energy feedback quality test results.
| Input power (W) | ATHD (%) | Power factor | 200 V | 250 V | 300 V | 200 V | 250 V | 300 V |
| 400 | 10.549 | 10.073 | 9.907 | 0.947 | 0.950 | 0.951 | 800 | 5.183 | 5.313 | 5.421 | 0.987 | 0.986 | 0.985 | 1200 | 3.507 | 3.823 | 3.806 | 0.995 | 0.994 | 0.992 | 1600 | 2.922 | 3.412 | 3.712 | 0.997 | 0.996 | 0.994 | 2000 | 2.534 | 2.784 | 2.963 | 0.998 | 0.997 | 0.997 | 2400 | 2.474 | 2.934 | 3.043 | 0.998 | 0.996 | 0.997 | 2800 | 2.403 | 2.555 | 2.887 | 0.998 | 0.998 | 0.998 | 3200 | 2.784 | 2.504 | 2.784 | 0.998 | 0.998 | 0.998 |
|
|