Research Article

Performance Analysis of Natural γ-Ray Coal Seam Thickness Sensor and Its Application in Automatic Adjustment of Shearer’s Arms

Table 1

Analysis of coal seam thickness measurement error.

Count value (pulse/0.5 s)222193186167157

Actual coal seam thickness (mm)050100150200

Instrument measurements value (mm)−16.45981.1158227

Absolute error value (mm)−16.49−18.9827

Relative error value (%)4.5−9.5413.5