Research Article
Control Algorithm for Equal Current Sharing between Parallel-Connected Boost Converters in a DC Microgrid
Table 4
Simulation results with the proposed algorithm.
| Time (sec) | (), (V) | (), (A) | current sharing differences |
| 0–2.5 | (12.054, 12.052), 11.93 | (0.3085, 0.3085), 0.616 | 0 | 2.5–5 | (11.97, 11.968), 11.792 | (0.443, 0.443), 0.886 | 0 |
|
|