Research Article
Design of PV, Battery, and Supercapacitor-Based Bidirectional DC-DC Converter Using Fuzzy Logic Controller for HESS in DC Microgrid
Table 2
Comparison of proposed FLC with conventional PI.
| Time domain parameters | Scenarios | Step rise in PV | Step decrease in PV | Conventional PI [26] | Proposed FLC | Conventional PI [26] | Proposed FLC |
| Settling time (ms) | 220 | 33 | 220 | 35 | Maximum peak overshoot (Mp) in % | 22.9% | 19% | 27% | 22% |
|
|