Research Article
An Improved Walsh Function Algorithm for Use in Sinusoidal and Nonsinusoidal Power Components Measurement
Table 1
The result of case A.
| FFT approach | Active power (watts) | Reactive power (var) |
| Phase a | 1181.1 | 944.8 | Phase b | 214.1 | 746.5 | Phase c | 492.6 | 1039.1 |
| Total | 1887.8 | 2730.4 |
| Proposed IWF method | ā | ā |
| Phase a | 1180.7 | 944.5 | Phase b | 214.8 | 746.7 | Phase c | 493.5 | 1040.2 |
| Total | 1889 | 2731.4 |
|
|