Production cost reduction of 15 heat files.

Heat file number Ratio of the costs by optimal control and manual control Cost saving

1 0.86 14%
2 0.9 10%
3 0.9 10%
4 0.9 10%
5 0.9 10%
6 0.86 14%
7 0.93 7%
8 0.84 16%
9 0.87 13%
10 0.91 9%
11 0.78 22%
12 0.9 10%
13 0.81 19%
14 0.82 18%
15 0.84 16%