Research Article

Development of a Cost-Effective Solar/Diesel Independent Power Plant for a Remote Station

Table 2

The electrical load (daily load demands) data for remote station.

Time123456789101112131415161718192021222324Total (watt)Total (kwatt)

00:00–01:005405400.54
1:00–2:005405400.54
2:00–3:005405400.54
3:00–4:005405400.54
4:00–5:005405400.54
5:00–6:005405400.54
6:00–7:0000
7:00–8:0000
8:00–9:003600043686080880036961200358809602496.024
9:00–10:0036000436860808800369612003840358809986499.864
10:00–11:003600043686080880036961200111944004201320038408312383.123
11:00–12:003600043686080880036961200111944004201320038408312383.123
12:00–13:00360004368608088003696120072044004201320038408272482.724
13:00–14:00360004368608088003696120072016.160067544004.564204805001320038403757652000155.988295.5688.29556
14:00–15:00360004368608088003696120072016.160067544004.564204805001320038403757652000155.988295.5688.29556
15:00–16:00360004368608088003696120072016.160067544004.564204805001320038403757652000155.988295.5688.29556
16:00–17:0000
17:00–18:0000
18:00–19:005405400.54
19:00–20:005405400.54
20:00–21:005405400.54
21:00–22:005405400.54
22:00–23:005405400.54
23:00–00:005405400.54
716224.7716.2247