Research Article

Bagasse Electricity Potential of Conventional Sugarcane Factories

Table 1

Heat-to-power ratios and efficiencies of cogeneration unit.

Cogeneration systemHeat-to-power ratioElectrical efficiency (%)Total energy efficiency (%)

1Back pressure steam turbine4-14.314-2884-92
2Extraction-condensing turbine2-1022-4060-80
3Gas turbine1.3-224-3570-85
4Combined cycle1-1.734-4069-83
5Reciprocating engine1.1.-2.533-3575-85