Research Article

Evaluating the Effectiveness of a Commercial Portable Air Purifier in Homes with Wood Burning Stoves: A Preliminary Study

Table 2

Home B mean concentrations (particle/m3) measured with the Lighthouse, lower and upper confidence intervals, and percent changes (%).

Air purifier offAir purifier on
Particle cutpoint (μm)Mean concentration (p/m3)LCI (p/m3)UCI (p/m3)Mean concentration (p/m3)LCI (p/m3)UCI (p/m3)Percent changeP value

0.326,010,21816,452,69741,119,7874,542,5542,870,5097,181,365−82%.001
0.52,533,9761,938,4513,312,786441,088337,425576,655−83%.000
1569,264423,285765,58885,97463,927115,636−85%.000
2.5206,282126,121337,72932,66319,95053,477−84%.000
531,35116,93358,0476,0393,26211,181−81%.002
10
 Day7,3474,20912,8231,6218573,072−78%.002
 Night1,2396542,347273157478−78%.002