Research Article

Using CO2 to Determine Inhaled Contaminant Volumes and Blower Effectiveness in Several Types of Respirators

Table 1

Summary of results.

RespiratorBlower flow rate (L/min)Exhaled volume (L)CO2  ratioWearer protection factorLeakage volume (L)Inhaled volume (L)Blower contribution  (L)Total blower volume  (L)Blower effectiveness

Racal PAPR191–2002.410.841.22.022.660.432.420.18
Centurion PAPR88–1012.370.2540.602.661.991.171.70
3M hood PAPR157–1612.390 02.632.631.871.41
3M PAPR121–2782.420 02.622.622.511.04
SE 400 PAPR64–3222.320 02.582.582.900.89
SE 400 APR (blower off)(0–284)2.370.048210.112.582.462.500.98
FRM 40 APR0–2892.370.057180.142.622.472.510.99