Research Article

Comparative Assessment of Particulate Air Pollution Exposure from Municipal Solid Waste Incinerator Emissions

Table 1

Source characteristics of the two inclusive municipal solid waste incinerators.

IncineratorCountyPermitted throughput (tonnes/year)FlueStack height (m)Stack diameter (m)Flue exit flow rate (m3/s)Flue exit velocity (m/s)Temperature (°C)

Crymlyn BurrowsNeath Port Talbot (South Wales)52,5001400.9512.317.6136
Marchwood Hampshire (England)210,0001
2
65
65
1.25
1.25
30.3
30.9
24.7
25.2
150
148

Flue exit flow rate, velocity, and temperature for Crymlyn Burrows provided are a mean of biannual measurements for most years of operation, whereas for Marchwood these measures are single measures derived from the permit application.