Preliminary Study: Environmental Assessment of Perchloroethylene in Dry-Cleaning Facilities in the UAE

Table 2

Comparison of the concentration of PERC (in ppm) from each dry-cleaning facility with the International Standards and UAE Standards.

Dry-cleaning facility AACGIH STEL: 100 ppm (as a 15 min TWA)OSHA ceiling: 200 ppm (for 5 min in any 3 h period).UAE Standards (AD EHSMS RF STEL): 100 ppm.

Position 1: 7.71–9Below limitBelow limitBelow limit
Position 2: 150–200Above limitMax. concentration on boundariesAbove limit
Position 3: 10–18Below limitBelow limitBelow limit

Dry-cleaning facility BACGIH STEL: 100 ppm (as a 15 min TWA)OSHA ceiling: 200 ppm (for 5 min in any 3 h period)AD EHSMS RF STEL: 100 ppm
Position 1: 10–75Below limitBelow limitBelow limit
Position 2: 51–63Below limitBelow limitBelow limit
Position 3: 7–8.4Below limitBelow limitBelow limit

Dry-cleaning facility CACGIH STEL: 100 ppm (as a 15 min TWA)OSHA ceiling: 200 ppm (for 5 min in any 3 h period)AD EHSMS RF STEL: 100 ppm
Position 1: 4–10Below limitBelow limitBelow limit
Position 2: 60–510Max. concentration above limitMax. concentration above limitMax. concentration above limit
Position 3: 3–8.4Below limitBelow limitBelow limit

Dry-cleaning facility DACGIH STEL: 100 ppm (as a 15 min TWA)OSHA ceiling: 200 ppm (for 5 min in any 3 h period)AD EHSMS RF STEL: 100 ppm.
Position 1: 2.72–3.38Below limitBelow limitBelow limit
Position 2: 60–240Max. concentration above limitMax. concentration above limitMax. concentration above limit
Position 3: 1.15–2.33Below limitBelow limitBelow limit