Research Article

Efficiency of Treatment Plant and Drinking Water Quality Assessment from Source to Household, Gondar City, Northwest Ethiopia

Table 2

Mean ± SD of physicochemical and bacteriological analysis of water samples at different sampling points in Gondar city, Northwest Ethiopia, June 30 to August 30, 2020.

ParametersSource pointDisinfection pointMain distributionTap water

pH7.17 ± 0.326.27 ± 0.156.24 ± 0.076.88 ± 0.05
Temperature (°C)24 ± 120.33 ± 1.5319.67 ± 2.0825.3 ± 0.13
DO (mg/L)15 ± 118.33 ± 1.5319.17 ± 0.766.5 ± 0.04
Turbidity (NTU)84.3 ± 6.034.5 ± 0.744.77 ± 0.655.15 ± 0.006
TDS (mg/L)245.7 ± 10.762.33 ± 2.5262.3 ± 2.0850.7 ± 0.57
EC (μS/cm)153 ± 14.5164.3 ± 5.13168 ± 1.73170.6 ± 0.1
RC (mg/L)2.25 ± 0.162.95 ± 0.493.12 ± 0.60.19 ± 0.003
Fluoride (mg/L)2.7 ± 0.212.07 ± 0.251.85 ± 0.051.17 ± 0.009
Total hardness (mg/L)310.7 ± 9.02147.7 ± 2.5137.7 ± 11.262.7 ± 0.5
Total alkalinity (mg/L)138.7 ± 8.575.7 ± 2.173 ± 132 ± 0.1
Nitrate (mg/L)76.7 ± 7.648.7 ± 3.54.7 ± 1.53.84 ± 0.005
Sulphate (mg/L)139.7 ± 5.565.3 ± 7.659 ± 3.61.2 ± 0.008
Phosphate (mg/L)90.3 ± 4.542.8 ± 2.540.7 ± 1.51.73 ± 0.007
Iron (mg/L)1.2 ± 0.0.30.5 ± 0.150.48 ± 0.0250.15 ± 0.004
Manganese (mg/L)2.3 ± 0.20.28 ± 0.20.48 ± 0.240.53 ± 0.011
TC (CFU/100 mL)120.2 ± 0.7610.13 ± 0.3510.6 ± 0.115 ± 0.26
FC (CFU/100 mL)50.2 ± 0.610.49 ± 0.020.6 ± 0.11.51 ± 0.03

The parameter was significant at . DO = dissolved oxygen, TDS = total dissolved solid, EC = electrical conductivity, RC = residual chlorine, TC = total coliform, and FC = faecal coliform.