Research Article

Removal of Pathogens from Domestic Wastewater Using Small-Scale Gradual Hydroponics Planted with Duranta erecta, Addis Ababa, Ethiopia

Table 2

Mean influent and effluent concentration of HB, TC, and FC at different HRTs.

ParametersHRT (day)InfluentEffluentEthiopian standard
E-1
Avg ± SD
E-2
Avg ± SD
C-1
Avg ± SD
C-2
Avg ± SD

HB (CFU/100 ml)18.76 ± 0.0208.34 ± 0.0048.43 ± 0.0058.63 ± 0.0038.68 ± 0.003
TC (CFU/100 ml)5.54 ± 0.0055.17 ± 0.0215.25 ± 0.0185.46 ± 0.0115.49 ± 0.0122.6
FC (CFU/100 ml)4.55 ± 0.0204.25 ± 0.0474.34 ± 0.0324.47 ± 0.0314.50 ± 0.0301
HB (CFU/100 ml)38.81 ± 0.0198.21 ± 0.0098.45 ± 0.0068.55 ± 0.0048.66 ± 0.002
TC (CFU/100 ml)5.62 ± 0.0055.10 ± 0.0315.23 ± 0.0155.47 ± 0.0105.55 ± 0.0072.6
FC (CFU/100 ml)4.71 ± 0.0174.15 ± 0.0394.31 ± 0.0404.59 ± 0.0194.65 ± 0.0151
HB (CFU/100 ml)58.82 ± 0.0108.50 ± 0.0208.02 ± 0.0148.49 ± 0.0048.60 ± 0.003
TC (CFU/100 ml)5.71 ± 0.0044.87 ± 0.0545.02 ± 0.0315.54 ± 0.0095.57 ± 0.0042.6
FC (CFU/100 ml)4.77 ± 0.0093.81 ± 0.1104.19 ± 0.0494.61 ± 0.0184.67 ± 0.0121
HB (CFU/100 ml)78.95 ± 0.0167.06 ± 0.0987.96 ± 0.0158.38 ± 0.0078.56 ± 0.004
TC (CFU/100 ml)5.86 ± 0.0024.43 ± 0.1284.99 ± 0.0195.55 ± 0.0085.68 ± 0.0072.6
FC (CFU/100 ml)4.96 ± 0.0083.80 ± 0.1254.17 ± 0.0464.68 ± 0.0134.79 ± 0.0111

Standard deviation.