Table of Contents Author Guidelines Submit a Manuscript
Journal of Healthcare Engineering
Volume 2017, Article ID 1587670, 6 pages
https://doi.org/10.1155/2017/1587670
Research Article

A Strain Feedback Compensation Method during Cell Tensile Experiments

College of Materials Science and Engineering, Sichuan University, Chengdu 610065, China

Correspondence should be addressed to Yuanwen Zou; nc.ude.ucs@wyz

Received 13 February 2017; Revised 30 March 2017; Accepted 23 April 2017; Published 18 June 2017

Academic Editor: Liping Wang

Copyright © 2017 Rong Zhou et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. H. M. Powell, K. L. Mcfarland, D. L. Butler, D. M. Supp, and S. T. Boyce, “Uniaxial strain regulates morphogenesis, gene expression, and tissue strength in engineered skin,” Tissue Engineering Part A, vol. 16, no. 3, pp. 1083–1092, 2010. View at Publisher · View at Google Scholar · View at Scopus
  2. Y. U. Lee, D. Hayman, E. A. Sprague, and H. C. Han, “Effects of axial stretch on cell proliferation and intimal thickness in arteries in organ culture,” Cellular and Molecular Bioengineering, vol. 3, no. 3, pp. 286–295, 2010. View at Publisher · View at Google Scholar · View at Scopus
  3. K. S. Kang, S. J. Lee, H. S. Lee, W. Moon, and D. W. Cho, “Effects of combined mechanical stimulation on the proliferation and differentiation of pre-osteoblasts,” Experimental & Molecular Medicine, vol. 43, no. 6, pp. 367–373, 2011. View at Publisher · View at Google Scholar · View at Scopus
  4. T. M. Maul, D. W. Chew, A. Nieponice, and D. A. Vorp, “Mechanical stimuli differentially control stem cell behavior: morphology, proliferation, and differentiation,” Biomechanics and Modeling in Mechanobiology, vol. 10, no. 6, pp. 939–953, 2011. View at Publisher · View at Google Scholar · View at Scopus
  5. D. Zhang, C. D. Eggleton, and D. D. Arola, “Evaluating the mechanical behavior of arterial tissue using digital image correlation,” Experimental Mechanics, vol. 42, no. 4, pp. 409–416, 2002. View at Publisher · View at Google Scholar
  6. A. Colombo, P. A. Cahill, and C. Lally, “An analysis of the strain field in biaxial Flexcell membranes for different waveforms and frequencies,” Proceedings of the Institution of Mechanical Engineers Part H: Journal of Engineering in Medicine, vol. 222, no. 8, pp. 1235–1245, 2008. View at Publisher · View at Google Scholar · View at Scopus
  7. B. D. Riehl, J. H. Park, I. K. Kwon, and J. Y. Lim, “Mechanical stretching for tissue engineering: two-dimensional and three-dimensional constructs,” Tissue Engineering Part B Reviews, vol. 18, no. 4, pp. 288–300, 2012. View at Publisher · View at Google Scholar · View at Scopus
  8. H. Zhang, The Study on the Biological Effects of Cyclic Substrate Strain on Human Pulmonary Epithelial Cells, [Ph.D. Dissertation], College of Bioengineering, Chongqing University, P. R. China, 2002.
  9. J. P. V. Geest, E. S. D. Martino, and D. A. Vorp, “An analysis of the complete strain field within Flexercell™ membranes,” Journal of Biomechanics, vol. 37, no. 12, pp. 1923–1928, 2004. View at Publisher · View at Google Scholar · View at Scopus
  10. W. G. Zhong, C. Xu, H. L. Mi, and F. Q. Zhang, “Stress analysis of silastic membrane in dynamic strain cell unit,” Journal of Medical Biomechanics, vol. 22, no. 2, pp. 121–126, 2007. View at Google Scholar
  11. X. L. Ma, S. Li, X. Fu et al., “Stress analysis and biocompatibility research on a cell carrier with silicone rubber membrane,” Journal of Medical Biomechanics, vol. 26, no. 5, pp. 426–431, 2011. View at Google Scholar
  12. B. Pan, K. Qian, H. Xie, and A. Asundi, “Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review,” Measurement Science & Technology, vol. 20, no. 6, p. 062001, 2009. View at Publisher · View at Google Scholar · View at Scopus
  13. W. H. Peters and W. F. Ranson, “Digital imaging techniques in experimental stress analysis,” Optical Engineering, vol. 21, no. 3, pp. 427–431, 1982. View at Publisher · View at Google Scholar
  14. T. C. Chu, W. F. Ranson, and M. A. Sutton, “Applications of digital image correlation techniques to experimental mechanics,” Experimental Mechanics, vol. 25, no. 3, pp. 232–244, 1985. View at Publisher · View at Google Scholar · View at Scopus
  15. F. Hild and S. Rous, “Digital image correlation: from displacement measurement to identification of elastic properties—a review,” Strain, vol. 42, no. 2, pp. 69–80, 2006. View at Publisher · View at Google Scholar · View at Scopus
  16. N. Mccormick and J. Lord, “Digital image correlation,” Materials Today, vol. 13, no. 12, pp. 52–54, 2010. View at Publisher · View at Google Scholar · View at Scopus
  17. J. Huang, X. Pan, X. Peng et al., “High-efficiency cell-substrate displacement acquisition via digital image correlation method using basis functions,” Optics & Lasers in Engineering, vol. 48, no. 11, pp. 1058–1066, 2010. View at Publisher · View at Google Scholar · View at Scopus
  18. J. C. Passieux, F. Bugarin, C. David, J. N. Périé, and L. Robert, “Multiscale displacement field measurement using digital image correlation: application to the identification of elastic properties,” Experimental Mechanics, vol. 55, no. 1, pp. 121–137, 2015. View at Publisher · View at Google Scholar · View at Scopus
  19. D. Zhang and D. D. Arola, “Applications of digital image correlation to biological tissues,” Journal of Biomedical Optics, vol. 9, no. 4, pp. 691–699, 2004. View at Publisher · View at Google Scholar · View at Scopus
  20. Z. Gao and J. P. Desai, “Estimating zero-strain states of very soft tissue under gravity loading using digital image correlation,” Medical Image Analysis, vol. 14, no. 2, pp. 126–137, 2010. View at Publisher · View at Google Scholar · View at Scopus
  21. G. Okotie, S. Duenwaldkuehl, H. Kobayashi, M. J. Wu, and R. Vanderby, “Tendon strain measurements with dynamic ultrasound images: evaluation of digital image correlation,” Journal of Biomechanical Engineering, vol. 134, no. 2, p. 024504, 2012. View at Publisher · View at Google Scholar · View at Scopus
  22. A. Karimi, T. Sera, S. Kudo, and M. Navidbakhsh, “Experimental verification of the healthy and atherosclerotic coronary arteries incompressibility via digital image correlation,” Artery Research, vol. 16, pp. 1–7, 2016. View at Publisher · View at Google Scholar · View at Scopus
  23. E. Rizzuto, S. Carosio, M. Faraldi, S. Pisu, A. Musarò, and Z. D. Prete, “A DIC based technique to measure the contraction of a skeletal muscle engineered tissue,” Applied Bionics and Biomechanics, vol. 2016, Article ID 7465095, 7 pages, 2016. View at Publisher · View at Google Scholar · View at Scopus
  24. E. Rizzuto, S. Carosio, and Z. D. Prete, “Characterization of a digital image correlation system for dynamic strain measurements of small biological tissues,” Experimental Techniques, vol. 40, no. 2, pp. 743–753, 2016. View at Publisher · View at Google Scholar · View at Scopus
  25. G. Lionello, C. Sirieix, and M. Baleani, “An effective procedure to create a speckle pattern on biological soft tissue for digital image correlation measurements,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 39, pp. 1–8, 2014. View at Publisher · View at Google Scholar · View at Scopus
  26. R. Keys, “Cubic convolution interpolation for digital image processing,” IEEE Transactions on Acoustics Speech & Signal Processing, vol. 29, no. 6, pp. 1153–1160, 1981. View at Publisher · View at Google Scholar · View at Scopus
  27. B. Pan, “Recent progress in digital image correlation,” Experimental Mechanics, vol. 51, no. 7, pp. 1223–1235, 2011. View at Publisher · View at Google Scholar · View at Scopus
  28. J. D. King, S. L. York, and M. M. Saunders, “Design, fabrication and characterization of a pure uniaxial microloading system for biologic testing,” Medical Engineering & Physics, vol. 38, no. 4, pp. 411–416, 2016. View at Publisher · View at Google Scholar · View at Scopus