Research Article

R Peak Detection Method Using Wavelet Transform and Modified Shannon Energy Envelope

Table 2

Performance of the proposed R peak detection method using the MIT-BIH arrhythmia DB with length 30 min.

RecordTotal beats (TP + FN)TP (beats)FN (beats)FP (beats)Se (%)+P (%)DER (%)Acc (%)

100227322721099.961000.04499.956
101186518641399.9599.840.21599.786
10221872187001001000100
10320842084001001000100
104222922281599.9699.780.26999.731
1052572256841799.8499.340.81899.189
106202720243599.8599.750.39599.606
107213721361199.9599.950.09499.906
108176317594599.7799.720.51299.491
109253225320110099.960.03999.961
111212421231099.951000.04799.953
11225392539001001000.000100.000
113179517941099.941000.05699.944
114187918781299.9599.890.16099.841
115195319530310099.850.15499.847
1162412240012299.5099.920.58399.420
117153515323199.8099.930.26199.740
118227822780210099.910.08899.912
119198719861299.9599.900.15199.849
121186318621199.9599.950.10799.893
12224762476001001000100
123151815180210099.870.13299.868
124161916190410099.750.24799.754
200260126001299.9699.920.11599.885
201196319603099.851000.15399.847
202213621351099.951000.04799.953
2032980295921899.3099.730.98099.029
205265626551099.961000.03899.962
207186018582599.8999.730.37799.625
208295529469399.7099.900.40799.594
209300530050110099.970.03399.967
210265026491299.9699.920.11399.887
21227482748001001000100
21332513251001001000100
214226222620110099.960.04499.956
215336333621099.971000.03099.970
217220822080110099.950.04599.955
21921542154001001000100
22020482048001001000100
221242724270110099.960.04199.959
222248324830110099.960.04099.960
22326052605001001000100
2282053205211299.9599.420.63499.370
230225622560210099.910.08999.911
23115711571001001000100
232178017800210099.890.11299.888
233307930763299.901000.16399.838
23427532753001001000100