Journal of Healthcare Engineering / 2017 / Article / Tab 1

Research Article

Semiautomatic Segmentation of Glioma on Mobile Devices

Table 1

The similar indicator of segmentations.

AlgorithmSI ≥ 75%SI ≥ 85%SI ≥ 90%
Number of samplesProportionNumber of samplesProportionNumber of samplesProportion

Our method10984.50%8565.89%4232.56%
Snake8968.99%7558.14%3930.23%
RegionGrow4837.21%3426.36%1914.73%
LuTA5240.31%3829.46%43.10%
CV3527.13%2217.05%21.55%

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.