Research Article

Effective Pneumothorax Detection for Chest X-Ray Images Using Local Binary Pattern and Support Vector Machine

Table 2

Comparisons of the accuracy, precision, and sensitivity for different patch sizes of the proposed method.

Patch sizeAccuracyPrecisionSensitivity

5 × 585.8%83.6%87.4%
7 × 784.1%84.4%85.5%
9 × 983.2%85.1%82.3%
11 × 1181.1%86.2%81.6%