Summary of performance characteristics of planar optical ultrasound transmitters.

AbsorberLayer structureThickness (μm)Pressure (MPa)−6 dB bandwidth (MHz)Laser power (mJ/cm2)Measurement distance (mm)

Carbon black [24]Single-layer250.15~4010.410
Carbon black [25]Single-layer110.8~20
AuNPs [34]Single-layer80–10000.01–0.189~43.67–131.8
CNTs [28]Multilayer2.6~803 mW/cm21.4
CNFs [31]Multilayer57.912.157.633.713.65
rGO [27]Multilayer11.10.5~6035.66
AuNP Array [32]Multilayer~4.50.5~6550.910