Research Article
3D Shape-Weighted Level Set Method for Breast MRI 3D Tumor Segmentation
Table 4
Accuracy, specificity, and false alarm rate (%) of the different algorithms and noise densities in 7 × 7 mask blurred computer-simulated images.
| Noise density | Methods | ACM | LSM | SLSM | 3D-LSM | 3D-SLSM |
| 5% | CCR | 88.22 | 98.5 | 99.16 | 98.87 | 99.21 | SP | 87.65 | 98.42 | 99.63 | 98.82 | 99.25 | FAR | 12.48 | 1.59 | 0.89 | 1.2 | 0.84 |
| 10% | CCR | 88.67 | 98.67 | 99.12 | 98.96 | 99.23 | SP | 88.14 | 98.62 | 99.66 | 98.93 | 99.29 | FAR | 11.99 | 1.4 | 0.93 | 1.11 | 0.81 |
| 15% | CCR | 87.42 | 98.74 | 99.09 | 98.99 | 99.19 | SP | 86.82 | 98.69 | 99.65 | 98.97 | 99.27 | FAR | 13.32 | 1.33 | 0.96 | 1.06 | 0.85 |
| 20% | CCR | 87.72 | 98.88 | 99.04 | 99.13 | 99.3 | SP | 87.15 | 98.85 | 99.68 | 99.15 | 99.43 | FAR | 13 | 1.19 | 1.02 | 0.92 | 0.74 |
| 25% | CCR | 87.89 | 98.86 | 98.99 | 99.11 | 99.23 | SP | 87.35 | 98.87 | 99.69 | 99.17 | 99.44 | FAR | 12.83 | 1.2 | 1.07 | 0.94 | 0.81 |
| 30% | CCR | 86.1 | 98.91 | 98.96 | 99.15 | 99.23 | SP | 85.43 | 98.95 | 99.71 | 99.23 | 99.46 | FAR | 14.72 | 1.16 | 1.11 | 0.9 | 0.82 |
| 35% | CCR | 86.27 | 98.91 | 98.87 | 99.19 | 99.21 | SP | 85.63 | 99.03 | 99.72 | 99.36 | 99.54 | FAR | 14.54 | 1.15 | 1.2 | 0.86 | 0.84 |
| 40% | CCR | 86.43 | 99 | 98.74 | 99.2 | 99.21 | SP | 85.79 | 99.18 | 99.73 | 99.44 | 99.64 | FAR | 14.37 | 1.05 | 1.34 | 0.84 | 0.84 |
| 45% | CCR | 84.41 | 98.94 | 98.63 | 99.16 | 99.13 | SP | 83.7 | 99.24 | 99.75 | 99.57 | 99.73 | FAR | 16.51 | 1.12 | 1.45 | 0.89 | 0.92 |
| 50% | CCR | 84.29 | 98.94 | 98.52 | 99.1 | 99.12 | SP | 83.55 | 99.37 | 99.78 | 99.66 | 99.66 | FAR | 16.63 | 1.12 | 1.57 | 0.95 | 0.93 |
|
|