Research Article
An Efficient Teager Energy Operator-Based Automated QRS Complex Detection
Table 2
Comparison of performance of our proposed method with other methods using MIT-BIH Arrhythmia Database (MIT-AD).
| Ref. | Method | DER | Se | P+ | Acc% |
| [10] | Low-pass filtering, high-pass filtering derivative filtering | 0.675 | 99.762 | 99.565 | 99.329 | [34] | Multiscale mathematical morphology | 0.0039 | 99.81 | 99.80 | 99.621 | [35] | Shannon energy envelope, Hilbert transform | 0.205 | 99.93 | 99.86 | 99.79 | [8] | Median filter, Savitzky–Golay, Kurtosis | 0.93 | 99.50 | 99.56 | 99.08 | [17] | Shannon energy | 0.164 | 99.95 | 99.88 | 99.84 | [18] | Wavelet transform, Shannon energy envelope | 0.163 | 99.93 | 99.91 | 99.838 | Proposed method | Teager energy operator | 0.291 | 99.74 | 99.97 | 99.71 |
|
|