Material parameters of Nitinol.
| Parameters | Values |
| Austenite elasticity, EA (MPa) | 51700 | Austenite Poisson’s ratio, νA | 0.3 | Martensite elasticity, EM (MPa) | 47800 | Martensite Poisson’s ratio, νM | 0.3 | Transformation strain, εL | 0.063 | Start of transformation loading, (MPa) | 600 | End of transformation loading, (MPa) | 670 |
|
|