Tab 5
/
Research Article
Feature Extraction of Surface Electromyography Using Wavelet Weighted Permutation Entropy for Hand Movement Recognition
Table 5
The commonly used time-domain feature set recognition accuracies (×100%).
Hand movement
Open
Close
Point
Ok
Yeah
Tripod
Grip
BP
0.70
0.89
0.85
0.69
0.94
0.82
0.70
SVM
0.84
0.95
0.92
0.85
0.83
0.93
0.77