Research Article
A New Multichannel Parallel Network Framework for the Special Structure of Multilead ECG
Algorithm 1
Preliminary processing of ECG.
| Symbol: | | SR: sampling rate | | : original ECG signal | | : ECG signal after removing baseline drift | | : filtered ECG signal | | : median filter parameters | | and Forder: high-pass/low-pass filter cut-off frequency and filter order | | round(): rounding function | | Process: | | A. Removing baseline drift in ECG signal | | 1 If round () is odd number | | Pmedian = round () | | else | | Pmedian = round () + 1 | | end | | 2 Pmedian point median filtering of to obtain | | B. The ECG signal is filtered | | 1 construct FIR filters based on fchp, fclp and Forder | | 2 filter x using filter to obtain |
|