Research Article

A New Multichannel Parallel Network Framework for the Special Structure of Multilead ECG

Table 7

Classification performance of different convolution kernel size.

Convolution kernel sizeACC (%)SE (%)SP (%)

(3,3)84.7682.5984.86
(5,5)87.8186.6087.63
(7,7)87.8186.0087.76
(9,9)87.2386.5686.09