Research Article

[Retracted] Joint Detection of Tap and CEA Based on Deep Learning Medical Image Segmentation: Risk Prediction of Thyroid Cancer

Table 5

Comparison of missed and misdiagnosis rates by three detection methods (%).

Testing methodMissed diagnosisMisdiagnosis

TAP detection45 (11.25)23 (5.75)
CEA detection47 (11.75)25 (6.25)
TAP + CEA detection8 (2.00)ab1 (0.25)ab
F36.15939.584
P0.0010.001

Note: compared with TAP test, a; compared with CEA test, b.