Research Article

A Dual Discriminator Adversarial Learning Approach for Dental Occlusal Surface Reconstruction

Table 2

Average results in terms of three quality metrics.

MetricPSNR ↑FSIM ↑SSIM ↑

Pix2pix [25]28.352 ± 1.8910.961 ± 0.0140.953 ± 0.011
CrownDesNet [24]28.917 ± 2.2480.975 ± 0.0090.966 ± 0.012
Dental-GAN [27]30.133 ± 2.0990.976 ± 0.0170.968 ± 0.014
DAIS [10]31.454 ± 1.7080.982 ± 0.0130.974 ± 0.010
GL-GAN [34]29.705 ± 2.4190.973 ± 0.0110.968 ± 0.016
DentalRecNet34.264 ± 1.2280.993 ± 0.0080.985 ± 0.005