Research Article

Outcomes of Emergency Transcatheter Aortic Valve Replacement

Table 2

Baseline echocardiographic variables.

Aortic valve area (cm2), mean (SD)0.96 (0.69)
 </ = 1.0 cm2, n (%)24 (77.4)

Mean valve gradient (mmHg), mean (SD)30.9 (14.8)
 >/ = 40 mmHg, n (%)7 (22.6)

Moderate/severe AR, n (%)9 (29.0)
 Moderate/ severe MR, n (%)8 (25.8)

LVEF (%), mean (SD)31.8 (15.3)
 LVEF<35%, n (%)19 (61.3)

Stroke volume index (ml/m2), mean (SD)31.4 (12.5)
 </ = 35 ml/m2, n (%)22 (71.0)

Estimated PASP (mmHg), mean (SD)47.0 (8.0)

AR: aortic regurgitation; MR: mitral regurgitation; LVEF: left ventricular ejection fraction; PASP: pulmonary artery systolic pressure.