Research Article

Efficacy of Low-Pressure Inflation of Oversized Drug-Coated Balloon for Coronary Artery Disease

Table 2

Procedural and follow-up quantitative angiographic characteristics in the crude cohorts.

LP group (n = 191)SP group (n = 135) value

Number of patients154119

Procedural devices
 DCA (%)9 (4.7)4 (3.0)0.57
 PTCRA (%)86 (45.0)38 (28.1)0.003
 B/A ratio0.76 ± 0.160.71 ± 0.170.11

Drug-coated balloon
 DCB/A ratio1.14 ± 0.221.03 ± 0.16<0.001
 Inflation pressure (atm)2.4 ± 1.27.1 ± 2.2<0.001
 Inflation time (sec)72.2 ± 39.864.8 ± 35.20.083

At PCI
 Reference diameter (mm)2.38 ± 0.672.57 ± 0.660.011
 Lesion length (mm)11.73 ± 6.8710.54 ± 5.690.10

MLD (mm)
  Preintervention (mm)0.89 ± 0.450.94 ± 0.480.38
  Postintervention (mm)1.74 ± 0.571.88 ± 0.490.027

Percent diameter stenosis
  Preintervention (%)62.9 ± 14.563.6 ± 15.10.69
  Postintervention (%)26.2 ± 11.924.1 ± 11.30.11

Acute gain (mm)0.85 ± 0.470.94 ± 0.470.091

Type of dissection (NHLBI)0.61
   A22 (11.5)17 (12.6)
   B23 (12.0)17 (12.6)
   C10 (5.2)3 (2.2)

Bailout stenting after DCB0 (0)0 (0)
 At follow-up
 Number of patients11488
 Angiography (%)145 (75.9)102 (75.6)1.0
 MLD (mm)1.76 ± 0.621.89 ± 0.590.094
 % diameter stenosis (%)29.24 ± 17.5525.77 ± 15.640.11
 Late lumen loss (mm)−0.00 ± 0.42−0.01 ± 0.420.86
 Restenosis (%)13 (9.0)10 (9.8)0.83

MLD, minimal lumen diameter; SD, standard deviation; PCI, percutaneous coronary intervention; DCA, directional coronary atherectomy; PTCRA, percutaneous coronary rotational atherectomy.