Four-Year Outcomes of Left Main Percutaneous Coronary Intervention with a Bioresorbable Scaffold in the Circumflex Ostium

Table 3

Quantitative coronary angiography data.

ParameterPre-procedure N = 46Post-procedure N = 464-year follow-up N = 33

Reference diameter, mm
 Left main3.54 ± 0.744.04 ± 0.374.05 ± 0.57
 LAD2.93 ± 0.583.60 ± 0.343.51 ± 0.42
 LCX2.82 ± 0.583.02 ± 0.382.88 ± 0.43

Minimum lumen diameter, mm
 Left main2.18 ± 0.623.72 ± 0.333.62 ± 0.51
 LCX2.41 ± 0.633.47 ± 0.383.27 ± 0.43
 LAD1.69 ± 0.462.80 ± 0.372.29 ± 0.80

% diameter stenosis, %
 Left main51.44 ± 16.078.37 ± 4.2311.96 ± 5.99
 LCX50.93 ± 14.9613.06 ± 5.1815.84 ± 11.69
 LAD68.00 ± 13.598.09 ± 4.3114.27 ± 6.12

Categorical variables are expressed as numbers and percentages. Continuous variables are indicated as mean ± SD.