Research Article
Four-Year Outcomes of Left Main Percutaneous Coronary Intervention with a Bioresorbable Scaffold in the Circumflex Ostium
Table 5
Predictors of primary outcome measure by binary logistic regression.
| Variable | Univariate | Multivariate | value | OR (95% CI) | value | OR (95% CI) |
| Age, years | 0.615 | 1.02 (0.94–1.11) | | | Male gender | 0.769 | 1.30 (0.23–7.32) | | | Dyslipidemia | 0.372 | 0.42 (0.06–2.79) | | | Diabetes mellitus | 0.848 | 0.80 (0.08–7.84) | | | Current smoker | 0.238 | 2.49 (0.55–11.31) | | | Heart failure | 0.317 | 2.39 (0.43–13.10) | | | Total cholesterol | 0.021 | 2.84 (1.17–6.90) | 0.226 | | LDL | 0.009 | 3.92 (1.40–11.00) | 0.120 | | Syntax score | 0.671 | 0.97 (0.84–1.12) | | | Cutting balloon diameter MB | 0.868 | 0.80 (0.06–10.89) | | | Cutting balloon diameter SB | 0.460 | 3.58 (0.12–105.10) | | | Cutting balloon side branch pre-dilatation | 0.015 | 0.13 (0.02–0.63) | 0.043 | 0.16 (0.03–0.94) | Stenting technique: mini-crush vs. T-stent | 0.315 | 0.46 (0.10–2.08) | | | LM-LAD stent length | 0.068 | 1.10 (0.99–1.22) | | | LM-LAD stent diameter | 0.734 | 1.59 (0.11–23.48) | | | Absorb length | 0.611 | 1.04 (0.90–1.20) | | | Absorb diameter | 0.153 | 0.24 (0.03–1.71) | | | Absorb size ≤2.5 mm | 0.048 | 5.12 (1.02–25.81) | 0.206 | | Pre-intervention IVUS MB and SB | 0.775 | 0.71 (0.06–7.71) | | | Post-intervention IVUS MB and SB | 0.008 | 0.07 (0.01–0.50) | 0.026 | 0.09 (0.01–0.75) | Pre-intervention OCT MB and SB | 0.775 | 1.42 (0.13–15.47) | | |
|
|
OR-odds ratio, MB-main branch, SB-side branch.
|