Research Article

Evaluation of Synthesized Nanohydroxyapatite-Nanocellulose Composites as Biocompatible Scaffolds for Applications in Bone Tissue Engineering

Figure 6

Cell viability in human osteoblasts exposed to the different nanoconstructs. The cells were exposed to 1 mg/mL of HAp, CNC, Hap > CNC, HAP = CNC, Hap > CNC + BMP-2, and HAP = CNC + BMP-2 nanoconstructs for 24 h and cell viability was determined with the MTS reduction assay. Values represent mean ± standard error of the mean (SEM) from three replicates. An asterisk indicates statistical significance in comparison with the untreated samples ().