Research Article
Thermal Stresses Analysis and Optimized TTP Processes to Achieved CNT-Based Diaphragm for Thin Panel Speakers
Table 10
Smaller-the-better
orthogonal array.
| Number | Factors | ΔdB values | SN | | | | | | | |
| 1 | 1/2 | Unidirectional | No | 80 | 2.62 | 2.67 | 2.66 | −8.4652 | 2 | 1/2 | 90° cross | 1 layer | 100 | 3.19 | 3.15 | 3.11 | −9.9667 | 3 | 1/2 | 45° angle | 2 layers | 120 | 2.59 | 2.5 | 2.62 | −8.2004 | 4 | 3/4 | Unidirectional | 1 layer | 120 | 4.39 | 4.42 | 4.51 | −12.948 | 5 | 3/4 | 90° cross | 2 layers | 80 | 3.21 | 3.19 | 3.14 | −10.0489 | 6 | 3/4 | 45° angle | No | 100 | 3.61 | 3.66 | 3.62 | −11.1983 | 7 | 1/1 | Unidirectional | 2 layers | 100 | 3.56 | 3.53 | 3.59 | −11.0292 | 8 | 1/1 | 90° cross | No | 120 | 4.31 | 4.37 | 4.28 | −12.7100 | 9 | 1/1 | 45° angle | 1 layer | 80 | 4.27 | 4.26 | 4.29 | −12.6154 |
|
|