Table 1

Adsorption behavior of MNPs and PAni/MNPs after 20 minutes. The analysis results obtained by developed ASV sensing system and AAS.

AdsorbentRemained As conc. by ASV (mg/l)Remained As conc. by AAS (mg/l)Difference
pH = 2pH = 5pH = 2pH = 5

MNPs0.0940.0250.0910.0283.2–10.7%
5% PAni0.0850.0100.0820.0093.6–10.0%
10% PAni0.0740.0120.0760.0131.3–7.6%
15% PAni0.0660.0190.0710.0224.6–13.6%

ASV measurement by developed sensor; using AAS method for confirmation.

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19. Sign up here as a reviewer to help fast-track new submissions.