Research Article

Morphology and Electrochemical Characterization of Electrodeposited Nanocrystalline Ni-Co Electrodes for Methanol Fuel Cells

Table 5

The EIS results of all electrodeposited nanocrystalline Ni-Co alloys tested in 1 M methanol + 0.5 M H2SO4.

Time (min) (KΩ) (Ω) (μF/cm2)

30 mA/cm2
151.827.91763.50.88
203.097.17863.30.86
302.397.71435.90.86
50 mA/cm2
157.997.42515.60.85
202.647.3118.80.86
301.716.96922.80.89
80 mA/cm2
153.67.13751.80.843
202.276.91627.80.845
302.537.12237.50.814
Stainless steel substrate
1037.27142. 90.89