Research Article

Engineering Quantum Dot (Cadmium Sulfide) on Antibodies for Fluoroimmunoassays

Figure 1

The end titer of purified antibodies after 14 weeks of immunization. (a) Best dilution factor for anti-transferrin and anti H. pylori is 1 : 500 and for anti-doxorubicin 1 : 100. (b) The humoral response at different time intervals during immunization. Antibody concentration was low at four weeks and reaches to a higher level after 12 weeks.