Research Article

Gold–Copper Film Electrode for Voltammetry Determination of Mercury in Water

Table 8

Anodic stripping voltammetry method for mercury determination.

No.VoltammetryElectrodeModifierDeposition time (s)Linearity (μg/L)LOD (μg/L)Real samplesRef.

1ASVGCSubmicrometer particulate Cu film30010–1000.1[12]
2ASVGCReduced graphene oxide/Au NPs nanocomposite6000.2–30.150.12Tap water[22]
4Au1200–500.05Tap water, pond water, wastewater[23]
5DP–ASVITOAu NPs3000.1–100.03Tap water, lake water, milk, soil sample[24]
6DP–ASVCarbon pasteKCdPb3(PO4)3 lacunar apatite900.04–20.2.23Sea water, fish samples[25]
7DP–ASVBDD302–102[26]
8DP–ASVBDD600.005–500.07Power plant samples[27]
9DP–ASVCarbon pasteAu NPs-bismuth2001–100.28Groundwater, soil samples[28]
10DP–ASVGCAu–Cu2501–50.09[17]
11DP–ASVCarbon pasteAu–Cu1801–50.13River water, groundwaterThis study

ITO: indium tin oxide; BDD: boron-doped diamond.