Research Article
Gold–Copper Film Electrode for Voltammetry Determination of Mercury in Water
Table 8
Anodic stripping voltammetry method for mercury determination.
| No. | Voltammetry | Electrode | Modifier | Deposition time (s) | Linearity (μg/L) | LOD (μg/L) | Real samples | Ref. |
| 1 | ASV | GC | Submicrometer particulate Cu film | 300 | 10–100 | 0.1 | — | [12] | 2 | ASV | GC | Reduced graphene oxide/Au NPs nanocomposite | 600 | 0.2–30.15 | 0.12 | Tap water | [22] | 4 | | Au | — | 120 | 0–50 | 0.05 | Tap water, pond water, wastewater | [23] | 5 | DP–ASV | ITO | Au NPs | 300 | 0.1–10 | 0.03 | Tap water, lake water, milk, soil sample | [24] | 6 | DP–ASV | Carbon paste | KCdPb3(PO4)3 lacunar apatite | 90 | 0.04–20. | 2.23 | Sea water, fish samples | [25] | 7 | DP–ASV | BDD | — | 30 | 2–10 | 2 | | [26] | 8 | DP–ASV | BDD | — | 60 | 0.005–50 | 0.07 | Power plant samples | [27] | 9 | DP–ASV | Carbon paste | Au NPs-bismuth | 200 | 1–10 | 0.28 | Groundwater, soil samples | [28] | 10 | DP–ASV | GC | Au–Cu | 250 | 1–5 | 0.09 | — | [17] | 11 | DP–ASV | Carbon paste | Au–Cu | 180 | 1–5 | 0.13 | River water, groundwater | This study |
|
|
ITO: indium tin oxide; BDD: boron-doped diamond. |