Grid sensitivity tests.


0.0100785.53415.10895.11816.73897.86617.20498.60117.32698.44017.291
0.1007937.2596.61937.6146.68137.7136.70037.6976.69737.5636.6712
0.2004430.1555.39930.2615.41930.2755.42330.2795.42430.1325.3960
0.3994525.4874.62725.4654.62525.5204.63725.5264.63825.3784.6099
0.7501523.0194.27622.9924.27423.0654.28823.0624.28822.9274.2622
0.9936722.2554.19722.2454.19822.3104.21222.3074.21122.1784.1861
Err. Max.13.11%12.62%3.37%3.19%0.60%0.62%0.59%0.614%Ref.Ref.