Charging-station information reliability requirement of LED light source and LAMP in current standards [23].

Test itemStandardsDescriptionsRemark

Lumen maintenanceIES LM-80-08/Energy Star6000 hr. life test at 3 different case temperatures: 55°C and 85°C, as defined by the manufacturer10 samples by Energy Star
Rapid-cycle stress testEnergy StarCycle times: 2 minutes on, 2 minutes off. Lamp cycled once for every two hours of required minimum life10 samples by Energy Star
Lumen maintenanceIEC/PAS 626126000 hits life test at 45°C ambient temperatureSample size 10
Rapid-cycle stress testIEC/PAS 62612Cycle times: 30 sec. on, 30 sec. off. Lamp cycled once for every two hours of required minimum life
Thermal shockIEC/PAS 62612-10°C~50°C 1 hr. dwell 5 cycles