Research Article
Electrochemical Determination of Uric Acid in Urine by Using Zeolite Imidazolate Framework-11 Modified Electrode
Table 3
Comparison of the present with other modified electrodes.
| Modified electrode | Linear range (μM) | Limit of detection (μM) | Sensitivity (μA·μM–1·cm–2) | Reference |
| Methylcellulose/graphene oxide/iron oxide nanohydrogel/GCE | 0.5–140 | 0.17 | 28.95 | [32] | Zinc Tetraaminophthalocyanine functionalized graphene nanosheets/GCE | 0.5–100 | 0.15 | 13.82 | [33] | Ordered mesoporous carbon (OMC) functionalized with ferrocene carboxylic acid | 30–390 | 1.8 | 0.317 | [8] | Pyrolytic graphite activated electrode | 2.5 –30 | 1.4 | 7.700 | [34] | Uricase-thionine-single-walled carbon nanotube modified electrode | 2–2000 | 0.50 | 0.09 | [35] | Poly(brilliant green) and poly(thionine) modified carbon nanotube coated carbon film electrode | 2–100 | 0.6 | 0.248 | [36] | Uricase/carbon nanotube /carboxymethylcellulose electrode | 20–5000 | 2.8 | 0.233 | [9] | ZIF-11/GCE | 50–540 | 0.48 | 2.80 | Present work |
|
|