Research Article

Optimization of Plasma Arc Cutting Parameters on Machining of Inconel 718 Superalloy

Table 5

Analysis of variance for HAZ.

SourceDFAdj SSAdj MS-value value

Regression4.11.313700.353424.580.085
Arc current (Amps)11.255841.2558416.270.016
Cutting speed (millimeter/minute)10.145700.145701.890.241
Gas pressure (Bar)10.012150.012150.160.712
Stand-off distance (millimeter)10.000000.000000.000.994
Error4.10.308790.07720
Total8.11.72249